Many newer Cornell homes put the garage off a rear lane or detached from the house. Charging there is easy to enjoy, but the electrical job is bigger than an attached garage because power has to travel underground from the house.
What the job involves
- Underground feeder. A conduit run (or other code-approved underground cable) from the house panel to the garage at the required depth.
- Crossing hard surfaces. Driveways, patios or walkways may need boring or cutting, which affects price.
- Garage subpanel. Often a small subpanel in the garage feeds the charger and leaves room for future circuits.
- Locates and permit. Utility locates before digging, and the ESA Notification of Work and inspection like any other installation.
Cost
Expect roughly $3,000 to $6,000+, depending on distance, surface and whether a subpanel is needed. We itemize trenching separately so you can see exactly where the money goes.
Ways to keep it sensible
- Pick the shortest practical route and mount the charger on the wall nearest the feeder.
- Think ahead: a larger conduit or subpanel now makes a second charger cheap later.
- Do the trench when you are already landscaping or repaving, if you can.
Compare the options on our pricing page.